PTMS LITHIUM COBALT ACID MATERIAL MAGNETIC field The working principle of PTMS Lithium cobalt acid material magnetic field is: the magnetic field is generated by electromagnetic induction, so that the screen is magnetized and magnetic. When the material is fed from the feeding mouth on the equipment, the non-magnetic material can pass through, and the magnetic material is adsorbed by the screen. In order to ensure the smooth passage of the material, the sieve and the vibrator are connected to vibrate at a certain frequency. The equipment requires controlled temperature cooling to ensure magnetic strength.
PTMS LITHIUM COBALT ACID MATERIAL MAGNETIC was used to carry out two experiments with magnetic intensity of 12000Gs and 6000Gs respectively. Each experimental sample passes through the screen for 3 times. After the sample passes through the screen for 3 times, the magnetic force is turned off, the magnetic material is recovered, the screen is removed, and the magnetic material attached to the screen is recovered.
Before iron removal, the iron content of the sample was 16mg. kg-i. In the case of PTMS LITHIUM COBALT ACID MATERIAL MAGNETIC strength of 12000Gs, after removing iron once, the iron content of the product decreased from 16ppm to 1ppm, but the product rate was low, with 93.6%. Lithium battery material. If the magnetic strength is changed to 6000Gs, after removing iron twice, the iron content of the product is Sppm, but the product rate is slightly higher, greater than 98%.